In this guide
This article is part of our wider coverage of home automation in Hyderabad. It pairs well with our guides to reading a home automation quotation and the scene matrix, which is the next step after the device list.
What the designer needs before counting
- The floor plan with room names, doors and windows, and ideally the furniture layout, because bed and sofa positions decide where keypads go.
- The electrical or lighting layout, showing switch points and how fittings are grouped into circuits.
- Window sizes and types, including which windows get curtains, sheers, or both.
- A short brief: who lives there, which rooms matter most, any security needs, and the budget range.
For this example: a 3BHK of about 1,800 sq ft with a foyer, an L-shaped living and dining room, a kitchen with a utility, a master bedroom with a walk-in wardrobe, a second bedroom, a kids’ room, three bathrooms and two balconies.
The method: four passes over the plan
- Loads: mark every lighting circuit, curtain track and AC that will be automated. Each dimmable or separately controlled lighting circuit is a channel.
- Controls: mark every place a person needs a keypad — room entrances, bedsides, and any second entrance — and what each must do.
- Sensing: mark doors to monitor, corridors for night lighting, and any security points.
- Network: place the gateway near the router and check that mains-powered devices are spread through the home so the Zigbee mesh reaches every corner.
The worked example, room by room
| Room | Lighting circuits | Curtains | Keypads | Sensors | AC in scenes |
|---|---|---|---|---|---|
| Foyer | 2 (ceiling, accent) | 0 | 1 (Welcome, All Off, Away) | Main door sensor | – |
| Living | 4 (downlights, cove, wall accent, TV backlight) | 2 (curtain + sheer) | 1 | – | 1 |
| Dining | 2 (pendant, downlights) | 1 | 1 | – | – |
| Kitchen and utility | 2 (ceiling, under-cabinet) | 0 | 0 (ordinary switches) | – | – |
| Corridor | 1 | 0 | 0 | 1 motion sensor | – |
| Master bedroom | 3 (ceiling, cove, bedside) | 2 (curtain + sheer) | 3 (door, both bedsides) | – | 1 |
| Walk-in wardrobe | 1 | 0 | 0 | 1 motion or door sensor | – |
| Second bedroom | 2 | 1 | 2 (door, bed) | – | 1 |
| Kids’ room | 2 | 1 | 2 (door, bed) | – | 1 |
| Balconies | 2 | 0 | 0 (on living scenes) | Balcony door sensor | – |
| Bathrooms | Not automated | – | – | – | – |
Two choices in this plan are worth noticing. The kitchen and bathrooms stay on ordinary switches because their use is short and practical. The balcony lights ride on the living room scenes instead of getting their own keypad.
The final device list
| Item | Quantity | Notes |
|---|---|---|
| Automated lighting circuits | 21 | Kitchen included as on/off on scenes; bathrooms excluded |
| Wall keypads | 10 | Foyer, living, dining, 3 in master, 2 each in other bedrooms |
| Motorised curtain tracks | 7 | Two double-layer windows count as four tracks |
| ACs controlled in scenes | 4 | Living and three bedrooms |
| Door sensors | 2 | Main door and balcony |
| Motion sensors | 2 | Corridor and wardrobe |
| Gateway | 1 | Near the router in the living area |
Note how the count follows from circuits and control points, not from the number of light fittings. Twelve downlights on one circuit are one channel; one pendant on its own circuit is also one channel.
Questions that change the count
- Do you want separate control of each layer? Splitting a living room’s downlights into two groups adds a channel but allows a softer evening scene.
- Sheers and curtains, or curtains only? Double layers double the tracks on that window.
- Keypads on both sides of the bed? Adding a second bedside keypad is one of the most-appreciated small extras.
- Security scope: a smart lock, more door sensors or cameras add devices but little complexity.
- Phasing: you can wire for everything now and automate the second bedroom later. See how to future-proof a new home for automation.
How to check a device list you have been given
- Find every bed and every room entrance on your plan and check there is a control within reach.
- Count your windows and match them to the curtain line, layer by layer.
- Ask for the circuit grouping, so you can see why each channel exists.
- Check where the gateway goes and how the mesh reaches far rooms.
- Ask what is deliberately left out and why; a good designer can explain every exclusion.
How Pert delivers it — a designed solution, not a DIY kit
At Pert, the device list is the output of a design, not a starting price. We study your floor plan and electrical layout, visit the site, and build the plan room by room: circuits for tunable and dimmable lighting, tracks for motorised curtains, Stella keypad positions and engraving, security devices, and the Pert gateway that runs it all on one Zigbee network. Our team then installs, commissions and fine-tunes exactly what was designed. When you compare installers, our guide to the best home automation companies in Hyderabad lists what to ask.
Have a floor plan for a Hyderabad home? Share it with us and we will turn it into a clear, explained device list for lighting, curtains, keypads, scenes and security. Request a consultation →
Frequently asked questions
How many keypads does a 3BHK need?
A typical 3BHK needs around eight to twelve keypads: one at the foyer, one each in the living and dining areas, and one at the door plus one or two by the bed in each bedroom. Kitchens and bathrooms often keep ordinary switches. Your furniture layout and number of entrances decide the final count.
Is the device list based on the number of lights?
No. It is based on lighting circuits, or channels, and control points. A group of downlights wired together is one channel, while a pendant on its own circuit is another. That is why the electrical layout matters as much as the floor plan.
Why do some windows need two curtain motors?
Windows with both a blackout curtain and a sheer have two tracks, and each motorised track needs its own motor. That lets you close only the sheer for daytime privacy and glare, or both layers at night.
What should I check in a home automation device list?
Check that every room entrance and bed has a control within reach, that every window layer has a track, that the circuit grouping is explained, that the gateway position covers the home, and that anything left out was left out deliberately.