Pert Multi Sensor is a Wi-Fi enabled device to control the IR remote based appliances. All appliances can be remote controlled by only one smart phone. It has got 3 Home monitoring sensors like Temperature, luminosity and smoke which helps your monitor and protect your house Supports home appliances like TV, Set Top Box, Air-conditioning, Loudspeaker Box, Motor Curtain.

SPECIFICATIONS

 

AC SPECIFICATIONS
Operating Input Power Range 90VAC-264VAC±5{%}, 47-63Hz. 6A Max
GENERAL SPECIFICATIONS
Power Consumption <0.2W no load <1.0W Loaded.
Temperature Operation 0°C to +50°C.

Storage -20°C to +70°C.

Relative Humidity Operating 5{%}RH to 95{%}RH Non-Condensing.

Storage 5{%}RH to 95{%}RH Non-Condensing.

Dimension 62mm x 62mm x 98mm
RF Frequency 2.45GHz

I. ABOUT PERT SENSOR

A) IR SENSOR
Pert Multisensor has 7 IR transmitters inside the box. This IR sensor covers 300Sq feet area in a closed room. PertMulti Sensor has an IR receiver inside the box. By using this receiver, the user can program the remotes in to the sensor.

B) TEMPERATURE SENSOR
PertMulti Sensor has a Temperature sensor at the bottom of side behind the enclosure.It senses the temperature from 2°C to 150°C with a 0.1°C resolution. The error percentage is ±2% on the nominal value.

C) LIGHT SENSOR
PERT Multi Sensor is has a light sensor on the back side bottom.
This sensor senses the light and displays the value in lux (Units of luminance).

II. INSTALLATION
The Wi-Fi signal should be greater than 75% at Pert Sensor installation location. Insert the input AC cable into any 3 Pin 6A Plug Point. Please note, this should be in the IR range (i.e: 300 sq ft from the appliances) Switch on the Pert device and Press the Smartconfig button located on behind of the device. The Led turns to Red color and the device is ready to configure, and can be configured manually like any other Pert device from the mobile app. After the configuration is complete, the user can control the IR devices from the PERT mobile application (with the available remotes)

Please note: If your remote is not available in the PERT remote library then you can add a remote.

III. Recommendations
1.The PERT sensor and IR appliances should be in the specified range of each other.
2.The manual remote and the mobile app keys should match, for the remote to be read.
3.While reading the remote, please wait for the completion of the reading of each button. Do not close the app while learning the remote. Or else the data will not save and function.
4.Light sensor will give you the accurate luminance (at bottom of the enclosure of the light sensor) but it will not give the data of surroundings.
5.Smoke/Gas detector sense the data only when the smoke or gas enters inside the enclosure.

IV. GUARANTEE
One year guarantee is provided by Pert InfoConsulting Pvt. Ltd. Guarantee is only applicable for electrical damages caused. If the user tries to service the board himself, the guaranty will not be covered. Guarantee is not applicable for any physical damages. The warranty will be considered void if the sticker is tampered / removed.

PERT PLUG is a smart Wi-Fi enabled device that lets you control your Air Conditioners , Geysers and electronic devices from your Smartphone from anywhere at any time.

PERT enables ON/OFF control of loads, schedules the ON/OFF of loads.

Typical Regular loads: Air Conditioner (2Ton Max), Geyser, Induction Stove, Electric Rice Cooker, Washing Machine, Light sources (CFL, LED lamps, etc), fridges, Television and Desktop computer.

SPECIFICATIONS

AC SPECIFICATIONS
Operating Input Power Range 90VAC-264VAC±5{%}, 47-63Hz.
Maximum Load 3KW Resistive Load @ 230VAC input.

3KVA Inductive Load @ 230VAC input.

GENERAL SPECIFICATIONS
Power Consumption <0.2W no load <1.0W Loaded.
Temperature Operation 0°C to +50°C.

Storage -20°C to +70°C.

Relative Humidity Operating 5{%}RH to 95{%}RH Non-Condensing.

Storage 5{%}RH to 95{%}RH Non-Condensing.

Dimension 80mm x 68mm x 80mm
RF Frequency 2.45GHz
Enclosure ABS Plastic.
  • INSTALLATION
    Check the Wi-Fi signal strength at the switch board, signal strength should greater than 75{%}.If it is less than 75{%} then, and adjust the router near to the switch board.

Pert Plug connects between the power source and load in series connection. First remove the power connection of the appliance, then insert the appliance plug into the Pert Plug Output socket.

Connect this Pert Plug into the power source.

plug diagramplug after

  • PERT CONFIGURATION

iOS Configuration Flow

Android Configuration Flow

  •  Recommendations
  1. Maximum Load Capacity for PERT is 16A only.
  2. Power Calculation = Voltage x Current rating specified on load.
    Current = Voltage / Power.
  3. 1000W is equal to 1KW.

PERT 8-Node Smart Switch is a smart Wi-Fi enabled device that lets you control your lights and electronic devices from your Smartphone from anywhere at any time.

PERT enables ON/OFF control of regular loads and also it can regulate dimmable loads.

Basically the loads are classified as follows.

Typical Regular loads: Light sources(CFL, LED lamps,  etc), fridges, Television, Desktop computer and other utility appliances.

Typical Dimmable loads: Incandescent   lamps, halogen lamps, dimmable CFL lamps, dimmable LED lamps, dimmable ceiling fans and other dimmable resistive and inductive loads.

SPECIFICATIONS

AC SPECIFICATIONS
Operating Input Power Range 90VAC-264VAC±5{%}, 47-63Hz, 3A Max.
Maximum Load per Node. 200W Resistive Load @ 230VAC input.

150VA Inductive Load @ 230VAC input.

Dimmer Output power for Inductive Loads 10VA – 150VA @ 230VAC.
GENERAL SPECIFICATIONS
Power Consumption <0.2W no load <1.0W Loaded.
Temperature Operation 0°C to +50°C.

Storage -20°C to +70°C.

Relative Humidity Operating 5{%}RH to 95{%}RH Non-Condensing.

Storage 5{%}RH to 95{%}RH Non-Condensing.

Dimension 114mm x 54.5mm x 23mm
RF Frequency 2.45GHz
Enclosure ABS Plastic FR Grade.
  • INSTALLATION

Check the Wi-Fi signal strength at the switch board, signal strength should greater than 75{%}.If it is less than 75{%} then, and adjust the router near to the switch board.

Open the switchboard top cover. Remove all the connections to the switches and label them with numbers based on switches position and numbers. Identify and separate the common line and neutral in the switchboard. Remove the line wire from the switches common point.

Take the PERT box and connect the Line and Neutral to PERT. Connect all loads wires to the output connector based on previous labels. The outputs number should match with previous switches connections numbers.

Remove the existing fan regulator, replace with PERT regulator and close the regulator back cover properly. Fix the fan regulator tightly to the switch board. If the fan regulator not required then, connect the jumper to the fan regulator cable (3 wires cable).

Connect the 10 pin cable wires individually to the switches based on previous switch sequence. Connect the ground in the switch board in place of common line in the switch board.

10 pin cable

Fit the pert properly inside the switch board. Verify all the connections and close the switch board.

  • PERT CONFIGURATION
    iOS Configuration Flow

Android Configuration Flow

  •  Recommendations
  1. Maximum Load Capacity for PERT is 3A only.
  2. Power Calculation = Voltage x Current rating specified on load.
    Current = Voltage / Power.
  3. 1000W is equal to 1KW.
  4. Maximum load capacity for each node is 200W.
  5. Don’t dim the non dimmable loads (Non dimmable CFL, LED Lamps).It causes failure of loads.
  6. Isolate the unused wires (Manual input) with any insulated tape.

PERT 4-Node Smart Switch is a smart Wi-Fi enabled device that lets you control your lights and electronic devices from your Smartphone from anywhere at any time.

PERT enables ON/OFF control of regular loads and also it can regulate dimmable loads.

Basically the loads are classified as follows.

Typical Regular loads: Light sources(CFL, LED lamps,  etc), fridges, Television, Desktop computer and other utility appliances.

Typical Dimmable loads: Incandescent   lamps, halogen lamps, dimmable CFL lamps, dimmable LED lamps, dimmable ceiling fans and other dimmable resistive and inductive loads.

SPECIFICATIONS

AC SPECIFICATIONS
Operating Input Power Range 90VAC-264VAC±5{%},, 47-63Hz, 3A Max.
Maximum Load per Node. 200W Resistive Load @ 230VAC input.

150VA Inductive Load @ 230VAC input.

Dimmer Output power for Inductive Loads 10VA – 150VA @ 230VAC.
GENERAL SPECIFICATIONS
Power Consumption <0.2W no load <1.0W Loaded.
Temperature Operation 0°C to +50°C.

Storage -20°C to +70°C.

Relative Humidity Operating 5{%}RH to 95{%}RH Non-Condensing.

Storage 5{%}RH to 95{%}RH Non-Condensing.

Dimension 92mm x 51mm x 23mm
RF Frequency 2.45GHz
Enclosure ABS Plastic FR Grade.
  • INSTALLATION

Check the Wi-Fi signal strength at the switch board, signal strength should greater than 75{%}.If it is less than 75{%} then, and adjust the router near to the switch board.

Open the switchboard top cover. Remove all the connections to the switches and label them with numbers based on switches position and numbers. Identify and separate the common line and neutral in the switchboard. Remove the line wire from the switches common point.

Take the PERT box and connect the Line and Neutral to PERT. Connect all loads wires to the output connector based on previous labels. The outputs number should match with previous switches connections numbers.

Remove the existing fan regulator, replace with PERT regulator and close the regulator back cover properly. Fix the fan regulator tightly to the switch board. If the fan regulator not required then, don’t remove the jumper.

Connect the 5 pin cable wires individually to the switches based on previous switch sequence. Connect the ground in the switch board in place of common line in the switch board.

5 pin cable

Fit the pert properly inside the switch board. Verify all the connections and close the switch board.

  • PERT CONFIGURATION

iOS Configuration Flow

Android Configuration Flow

  •  Recommendations
  1. Maximum Load Capacity for PERT is 3A only.
  2. Power Calculation = Voltage x Current rating specified on load.
    Current = Voltage / Power.
  3. 1000W is equal to 1KW.
  4. Maximum load capacity for each node is 200W.
  5. Don’t dim the non dimmable loads (Non dimmable CFL, LED Lamps).It causes failure of loads.
  6. Isolate the unused wires (Manual input) with any insulated tape.